Residential Air Tightness Testing Kits - for domestic air leakage testing

A Retrotec test kit is a flexible and cost-effective solution for domestic air leakage testing. The fan systems are suitable for testing both houses and flats. Use our equipment calculator to determine the type and number of fans you need.

Please note that under Approved Document L1A, domestic air tightness testers must either be a registered member of BINDT or work for an organisation which is UKAS accredited. Stroma offers the training required prior to beginning the BINDT registration process. More air tightness testing information.

Use the equipment calculator – the quick and easy way to determine your requirements.

Fan
System
Air Permeability
(m³/h.m² @ 50Pa)
Building
Envelope (m²)
No. of Fans

The Q46 and Q4E make air leakage testing quick, simple and effective. The compact and portable design facilitates transportation and eliminates concerns about site restrictions and problems with vehicle access. The cloth door kits comprise an easily assembled aluminium frame with extension cams that compress it into the doorway, trapping the cloth membrane in the process and sealing the opening effectively without the need for tape. The Q46 and Q4E are available for either 110V and 230V electrical supply or a combination of the two (3000 series fans only). Both can be left running continuously, a significant benefit for smoke pencil diagnosis.

Download our product specifications for further details of our range:

 

View our brochure

Kit Q46

Consists of DM-2A, a 2200 fan and a cloth door panel.

 

View our brochure

Kit Q4E

Consists of DM-2A, a 3300 fan and a cloth door panel.

  • Meet regulatory requirements from the initial stages of a development with a design review workshop
  • Stroma is an active member of the Institute for Sustainability in the Thames Gateway area

    More... »
  • Stroma provides compliance testing and consultancy for the UK's top 10 contractors
    [Construction News Top 100, November 2008]
  • Stroma is a UKAS accredited air leakage and acoustic testing body
  • Stroma is developing pioneering new techniques for determining the effectiveness of sustainable, remedial building works

    More... »
  • Stroma has successfully tested more than 5,000 structures, from simple dwellings and single enclosures through to complex public buildings and vast warehouses
  • Stroma delivers CPD on the 2010 Part L regulations for Wates Construction
  • Stroma participated in Shred-it’s recycling program and saved 28 trees from destruction in 2010
  • Use the equipment calculator – the quick and easy way to determine your requirements
  • Stroma has calibrated over 350 different fans and manometers
  • Stroma has been a door fan distributor for over 4 years
  • What is the RRO?
  • What type of building needs a fire risk assessment?
  • Stroma launches fire risk assessor training course
  • Fire risk assessments for all non-domestic buildings
  • Third party accredited Stroma Contracting specialises in the remedial fire protection and fire stopping works needed for RRO compliance
  • PART L The Impact on Air Tightness... Rob Coxon outlines the targets in air-tightness testing in new homes.
  • Put money saving at the top of your agenda... Reduce your energy bills and your carbon footprint
  • Airtight buildings.... Waste less energy and cause less CO2
  • Buildings don’t need to “breathe”, only people do! Therefore… “Build Tight – Ventilate Right”
  • The New Part L1A & L2A 2010 Air-Tightness Requirements
  • Fundamental Approaches Designing for Air-Tightness Under Part L, establish what the air-tightness target has to be....
  • All air-conditioning systems with an effective rated output of more than 12kW must be regularly inspected by an energy assessor every 5 years, since the 4th January 2011.